VCAP-NV Design 2020 3V0-41.19 Test Questions – VMware Advanced Design NSX-T Data Center 2.4 Exam

The Advanced Design NSX-T Data Center 2.4 exam (3V0-41.19) which leads to VMware Certified Advanced Professional – Network Virtualization 2020 certification is a 50-item exam, with a passing score of 300 using a scaled method. Candidates are given an appointment time of 105 minutes, which includes five-minute seating time and adequate time to complete the exam for non-native English speakers. Actual exam time is 100 minutes.

The PassQuestion VCAP-NV Design 2020 3V0-41.19 Test Questions is available in an easy format of Question and Answers. The very pattern of PassQuestion VCAP-NV Design 2020 3V0-41.19 Test Questions is easy to grasp and is user-friendly that you never feel the requirement of further guidance. If you have decided to pass VMware 3V0-41.19 test, PassQuestion VCAP-NV Design 2020 3V0-41.19 Test Questions are here to help you achieve your goal. We know better what you need to pass your 3V0-41.19 test. Get everything you need to pass your 3V0-41.19 test.

VCAP-NV Design 2020 3V0-41.19 Test Questions – VMware Advanced Design NSX-T Data Center 2.4 Exam

1. Which NSX-T feature is used to allocate the network bandwidth to business-critical applications and to resolve situations where several types of traffic compete for common resources?

 
 
 
 

2. An architect is helping an organization with the Physical Design of an NSX-T Data Center solution and resolving a network throughput bottleneck.

This information was gathered during a workshop:

– A VM running a business critical application Is peaking at ~5Gbps

– Current host uplink is configured as Active/Standby with two 10Gb NICs.

– The installed server NIC model does not support GENEVE offload.

– All VM traffic is East/West.

– The business critical application VM communicates with multiple client VMs.

Which should the architect recommend to improve vSphere VM throughput?

 
 
 
 

3. Which three must be taken into consideration when creating a Logical Design for a planned migration? (Choose three.)

 
 
 
 
 
 

4. An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.

This information was gathered during the Assessment Phase:

– Maximum performance and availability is required between the physical and virtual network.

– Load Balancing service is required for back-end web servers.

– NAT is required.

Which should the architect include in their design?

 
 
 
 

5. Which is associated with the Discover Task of the Engagement Lifecycle?

 
 
 
 

6. An NSX-T architect is working with a customer who wants to improve performance and future-proof

their workloads with a multi-site architecture.

A current-state analysis captured this information:

– Latency between sites Is 160ms.

– Bandwidth is 2Gbps.

– The MTU is 1600.

What two VMware design recommendations should the architect recommend to the organization to achieve future-proofing? (Choose two.)

 
 
 
 
 

7. An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.

This information was gathered during the Assessment Phase:

– There Isn’t much budget available for a new off-shore site.

– The new site is decentralized and no communication with the main data center is required.

– The design will need to cater for availability, upgrades, and failure scenarios.

Which three should the architect recommend In their design? (Choose three.)

 
 
 
 
 
 

8. Which three assessment findings are part of a Conceptual Design? (Choose three.)

 
 
 
 
 
 

9. An architect is helping an organization with the Physical Design of an NSX-T Data Center solution.

This information was gathered during a workshop:

– Some workloads should be moved to a Cloud Provider.

– Extend network’s VLAN or VNI across sites on the same broadcast domain.

– Enable VM mobility use cases such as migration and disaster recovery without IP address changes.

– Support 1500 byte MTU between sites.

Which should the architect include in their design?

 
 
 
 

10. An architect is helping an organization with the Logical Design of an NSX-T Data Center solution.

This information was gathered during the Assessment Phase:

– Customer Is concerned with NSX Manager availability.

– 3 cabinets/racks are available in the data center.

– No integration with 3rd party solution is required.

– There is no budget for physical equipment acquisition.

– The 3 cabinets/racks do not share the same L2 domain.

Which three should the architect include in their design to address the customer’s concern with NSX Manager availability? (Choose three.)

 
 
 
 
 
 

5V0-21.20 Practice Test Questions - VMware HCI Master Specialist
VCAP-NV Deploy 2020 3V0-643 Practice Test Questions

Leave a Reply

Your email address will not be published. Required fields are marked *